Acuson 6C1 probe for repair

Acuson 6C1 probe for repair, SN: 643***** Fault: 1. Housing damaged; 2. Probe cable broken; 3. Image with shadow and disturbance; 4. Scanhead aged ...
Contact Now

Add to Cart

Acuson 18L6 probe for repair

Acuson 18L6 probe for repair, SN: 335***** Fault: 1.Probe lens broken and soften; 2.Probe cable broken; 3.Scanhead aged Solution: Repair cable and ...
Contact Now

Add to Cart

Biosound CA431 Convex probe for repair

CA431 probe for repair, SN: 1****. Fault: Lens break. Solution: Replace lens. Repair cost: $***. Warranty: 90 days. Before repair and after repaired:
Contact Now

Add to Cart

BK Medical 9096 Robotic Ultrasound Probe For Repair

BK Medical 9096 Robotic Ultrasound Probe For Repair ► Brief Description Fault: All the outer skin of the cable is seriously damaged. Solution: Replace ...
Contact Now

Add to Cart

BK Medical 9048 Ultrasound Probe For Repair

BK Medical 9048 Ultrasound Probe For Repair ► Brief Description Fault: The housing break. Solution: Replace probe housings. ►Problem & Solutoin Brand ...
Contact Now

Add to Cart

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair ► Brief Description Fault: 1.No ultrasonic energy output. Ultrasonic crystal is damaged. ...
Contact Now

Add to Cart

OLYMPUS GIF-Q150 GASTROSCOPE SN:270**** FOR REPAIR

OLYMPUS GIF-Q150gastroscope, SN:270****. Test result: 1. With image; 2. Light bundlebreak badly; 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage ...
Contact Now

Add to Cart

OLYMPUS CF-Q180AI COLONOSCOPE SN:280**** FOR REPAIR

OLYMPUS CF-Q180AI colonoscope,SN:280****. Test result: 1. With image ; 2. 25% light bundle break ; 3. The insert tube is slightly aged, leakage at the ...
Contact Now

Add to Cart

GE RIC5-9-D PROBE SN:1870***** FOR REPAIR

GE RIC5-9-D Probe(SN:1870*****). Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost ...
Contact Now

Add to Cart

OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR

OLYMPUSTJF-Q180V duodenoscope, SN: 270****. Test result: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. ...